Calculator

Insulation R-value Calculator

Stack wall, roof or floor layers and get the total Rc, U-value and US R-value, with each layer's share and the Dutch new-build minimum to compare.

All calculators
Layers, inside to outside

Pick a material and type its thickness in millimetres. Have a product datasheet? Choose "Known R-value" and type the R it lists.

Rc
5.49
m²K/W, layers only
U-value
0.177
W/m²K, lower is better
US R-value
R-31
ft²·°F·h/Btu, R-32 with surfaces
Total with surfaces: Rt = 0.13 + 5.49 + 0.04 = 5.66 m²K/W
Indicative comparison, not a code check
  • Dutch new-build minimum for a wall: Rc 4.7. Above it.
  • US code (IECC 2021, zone 5): U at most 0.256 W/m²K (U-.045 in US units). Above it.

This compares layers only. An official check (NTA 8800 in the Netherlands) also counts metal fixings, joints, corners and other thermal bridges, so the real Rc can be lower. Have a builder or energy advisor confirm it before you apply for a permit.

Which layer does the work
  • Gypsum plasterboardR 0.061%
  • Stone woolR 4.0073%
  • OSB / plywoodR 0.092%
  • Wood fibre board (rigid)R 1.3324%

Layers follow the EN ISO 6946 method; studs use its combined method when you set a timber share. Metal fixings, gaps and corners are not counted. A cladding layer behind a ventilated gap does not count. Material values are typical figures with a spread between products: your product datasheet wins.

Insulation R-value Calculator

What This Calculator Does

This insulation R-value calculator adds up the layers of a wall, roof or floor and tells you how well the whole thing keeps heat in.

You get three numbers. Rc is the score of the layers together, the number Dutch and Belgian builders use. The U-value says how much heat leaks through, so lower is better. The US R-value is the same Rc in the American units you see on insulation packs in the US.

It also shows how much each layer adds, so you can see straight away which layer does the real work. For the basics behind these numbers, read how insulation traps air.

How To Use This Calculator

  1. In What are you insulating?, pick wall, roof or floor. This changes the U-value a little, because heat leaves a surface faster going up than going down.
  2. Under Layers, inside to outside, pick a material for each layer and type its thickness in millimetres.
  3. Have a product datasheet? Pick Known R-value and type the R it lists, in m²K/W. A US R-value? Divide it by 5.678 first.
  4. A closed, still air gap between two layers? Pick Still air gap and type its width.
  5. Building with timber studs? Tick Studs on the layer the studs run through, and type the Timber share: how much of the wall's face is wood. The UK convention (BRE BR 443) uses 15% for a timber-frame wall, or 12.5% with careful detailing.
  6. In US climate zone, pick your zone if you want the US code check. Zone 5 covers places like Chicago and Denver.
  7. Use Add layer for more rows and the bin icon to remove one.
  8. Read the result card. It compares your Rc with the Dutch new-build minimum and your U-value with the US code for your zone. That comparison is a guide, not a code check: see below.

The Formula, In Plain Words

Every material has a number called lambda (λ). It says how easily heat flows through one metre of it. Small lambda means a good insulator.

The R-value of one layer is its thickness in metres divided by its lambda. So 140 mm of stone wool at λ 0.035 gives 0.14 ÷ 0.035 = 4.0.

Add all the layer R-values together and you have Rc.

The air right next to each surface also slows heat down a little. The European standard EN ISO 6946 gives fixed values for this: 0.13 inside and 0.04 outside for a wall, 0.10 and 0.04 for a roof, 0.17 and 0.04 for a floor. Add those to Rc and you get the total, Rt.

The U-value is 1 divided by Rt. The US R-value is Rc times 5.678.

Studs make it a little harder, because heat can go two ways: through the insulation or through the wood. EN ISO 6946 works this out twice. Once as if the two paths sit side by side, which gives an upper limit. Once as if the stud layer were one mixed material, which gives a lower limit. The answer is the average of the two.

A Worked Example

The calculator starts with a timber-frame wall, inside to outside:

  • 12.5 mm gypsum board: 0.0125 ÷ 0.21 = 0.06
  • 140 mm stone wool: 0.14 ÷ 0.035 = 4.00
  • 12 mm OSB: 0.012 ÷ 0.13 = 0.09
  • 60 mm rigid wood fibre board: 0.06 ÷ 0.045 = 1.33

Rc is 0.06 + 4.00 + 0.09 + 1.33 = 5.49 m²K/W. That beats the Dutch minimum for walls of 4.7.

With the surfaces, Rt is 0.13 + 5.49 + 0.04 = 5.66. The U-value is 1 ÷ 5.66 = 0.177 W/m²K. In US units the wall is about R-31.

The stone wool does 73% of the work and the wood fibre 24%. The gypsum and OSB together add only 3%. They hold the wall together, they don't keep it warm.

Now add the studs: 15% timber through the stone wool. The wood path alone has Rt 2.73, because 140 mm of wood is only R 1.08. The upper limit comes out at 4.87 and the lower limit at 4.50. The average, 4.69, gives Rc 4.52 and a U-value of 0.213 W/m²K. The studs cost 0.97, about 18%, and the wall now falls just short of the Dutch 4.7.

Now try a 450 mm straw bale wall with the careful straw value. One bale gives Rc 5.63, about R-32 in US units, with no other insulation at all.

What To Watch Out For

Without a timber share, the calculator treats each layer as solid and even, so a timber-frame wall looks better than it is. Official Dutch and US checks include the studs, so set the timber share before you compare. Metal fixings, corners and gaps in the insulation are not counted.

So "Above it" on the result card is a rough guide, not proof that your wall meets the rules. In the Netherlands the official Rc is worked out with NTA 8800, which also counts fixings and air gaps in the insulation. Let a builder or energy advisor check the real design before you apply for a permit.

The lambda values are typical figures from published tables, such as the UK BRE guide BR 443 and the Upper Austria energy agency's insulation guide. Products vary, and a datasheet always beats a typical value.

Straw insulates better when heat flows across the stalks (λ 0.052) than along them (λ 0.080). How the stalks lie depends on how the bales are stacked, so pick the careful value if you're not sure.

A layer behind a ventilated gap, like timber cladding on battens, doesn't count. Outside air flows behind it, so it keeps the rain off but not the cold out.

Damp insulation works much worse than dry insulation. Read about moisture traps before you close up a wall.

Hard Words

TermWhat it means
Lambda (λ)How easily heat flows through a material, in W/m·K. Smaller is better.
R-valueHow well a layer resists heat flow, in m²K/W. Bigger is better, and layers add up.
RcThe R-values of all the layers added together, without the air at the surfaces.
RtRc plus the small extra resistance of the still air at each surface.
U-valueHow much heat leaks through each square metre for each degree of difference, in W/m²K. It is 1 divided by Rt. Smaller is better.
Thermal bridgeA spot where heat skips past the insulation, like a timber stud or a steel fixing.

Common Questions

How do you calculate the R-value of a wall?

Divide the thickness of each layer in metres by its thermal conductivity (lambda), then add the results. 140 mm of stone wool at λ 0.035 gives 4.0 m²K/W. A full timber-frame wall with gypsum board, stone wool, OSB and wood fibre board comes to about Rc 5.5.

What is the difference between Rc and U-value?

Rc is the resistance of the layers alone, so bigger is better. The U-value adds the still air at both surfaces and turns the result upside down: U = 1 ÷ (Rsi + Rc + Rse). It tells you how many watts leak through each square metre per degree, so smaller is better.

How do I convert a US R-value to metric?

Divide the US R-value by 5.678 to get m²K/W. An R-20 batt is about 3.5 m²K/W. To go the other way, multiply by 5.678. U-values convert the opposite way: a US U-factor times 5.678 gives W/m²K.

What Rc does a new Dutch house need?

The Dutch building rules (Bbl, article 4.152) ask for at least Rc 4.7 for walls, 6.3 for roofs and 3.7 for ground floors on new homes. Those values include the effect of studs, so set the timber share in the calculator before you compare. The official figure comes from an NTA 8800 calculation, so treat this calculator's answer as a first check only.

Which insulation has the best R-value per centimetre?

Of the common materials, PIR board scores highest, at about λ 0.022 to 0.025. Foam boards, mineral wool, wood fibre, hemp and sheep wool sit around 0.031 to 0.045. Straw is around 0.052 to 0.080, but a bale is so thick that a straw wall still scores well.

Sources

On this page